The new Amperis 3-Phase Relay testing AK-10 AC and DC Voltage Source ; AC Current Source ; Auxiliary AC/DC Power Supplies ; 8 possible configurations

3-Phase Relay testing, all-in-one design:

  • Embedded Windows CE & mouse & panel keyboard
  • 6.4” TFT LCD
  • Ethernet port for separate PC
  • Built in amplifier
  • 13 channels output: 6x20 (3x40A) / 7x130
  • High power: 6x420 VA, at 0…20A:
    • 3 x 520 VA, at 0….40A
    • 1 x 1000 VA, at 0….120A
  • High precision:
    • 0.14% reading + 0.06% range guaranteed at 0….300 V
    • 0.14% reading + 0.06% range guaranteed at 0….30 A
  • Amplitude, frequency and phase angle are adjustable respectively, independently and continuously

AK10 Series Protection Relay Test Set:

  • AK1030: 3x30A / 4x130V
  • AK1040: 3x40A / 4x130V
  • AK1063: 3x40A , 6x20A / 4x130V
  • AK1066: 3x40A, 6x20A / 7x130V
  • AK1030i: 3x30A / 4x300V
  • AK1040i: 3x40A / 4x300V
  • AK1063i: 3x60A , 6x30A / 4x300V
  • AK1066i: 3x60A, 6x30A / 7x300V

Technical Data:

Voltage generators

Setting Range

7-phase AC (L-N)

7x0…130V

1-phase AC (N-N)

1x0…260V

Power

7-phase AC (L-N)

7x70VA, at 0…130V

1-phase AC (N-N)

1x140VA, at 0…260V

Accuracy

<0.14% reading + 0.06% range guaranteed at 0...130V  <0.04% reading + 0.01% range typical at 0...130V

Resolution

1 mV

Current generators

Setting Range

6-phase AC (L-N)

6x0…20A

3-phase AC (L-N)

3x0…40A

1-phase AC (L-N)

1x0…120A

Power

6-phase AC (L-N)

6x150 VA, at 0…20A Max 250 VA. With the other current channels unload

3-phase AC (L-N)

3x300 VA, at 0…40A Max 450 VA. With the other current channels unload

1-phase AC (L-N)

1x900 VA

Accuracy

<0.14% reading + 0.06% range guaranteed at 0...20A  <0.05% reading + 0.02% range typical at 0...20A

Resolution

1 mA

Binary inputs

Number

8 Pairs

Compatible voltage

10V…250V/2A

Binary outputs

Number

4 Pairs

Capacity

250V/3A

Generators, general

Frequency

Range

0…1000 Hz

Accuracy / drift

<0.001 Hz at 10…450 Hz <0.01 Hz at 450…1000 Hz

Resolution

0.01 Hz

Phase

Range

-360º … +360º

Accuracy

< 0.2º

Resolution

0.1º

Time

Range

Infinite

Accuracy

1 ms

DC generators

Voltage ranges

0…300V / 180 W

Current ranges

0…20A / 300 W

Accuracy

<0.14%rd + 0.06%rg

Resolution

1mA; 1mV

Aux DC Supply

Range

0…300V / 0.6 A

Synchronization

Synchronization mode

GPS

Power supply

Nominal input voltage

220 V±20% Vac

Power

1000 VA

Nominal frequency

50/60 Hz±10%

Environmental conditions

Operation temperature

-5ºC…55ºC

Humidity range

≤90%, non-condensing

Harmonic superpose times

2…20

Weight

24 kg

Dimensions

360x460x140 (mm)

PC connection

RJ45

Note: the above specifications are valid at nominal voltage and ambient temperature of +25°C (+77°F). Specifications are subject to change without notice

Software Key Features

  • All-in-one.
  • Automatic test report creation, user friendly.
  • Control of 10 analog generators (6i & 4V) independetly.
  • Online vector display.
  • Power system model for dynamic testing.
  • Automatic compara actual characteristic with expected characteristic.
  • RIO / XRIO import and export facility.
  • Shot, Shearch, Check Point and Click testing.
  • Quick relay testing, facility in Manual Mode.
  • Graphical test modules and templates for testing of various relays.
  • COMTRADE (Common Format for Transient Data Exchange) format file supported.
Connectors 3-Phase Relay testing AK-10

Do you want to buy high quality Relay testing?

Inquire for our Relay testing prices.

Do not hesitate to contact us, call us today by phone (+34) 982 20 99 20. We are happy to help you.